Fan BD-Blue 130 ON/OFF 400-3-60 3.3A 43200m³/h

SKU
60-25-4587
Sales unit 1 pc
Availability Available for order

Basic data
Montiert Mounted
Thermal protection contact No
Type Installation at a wall
Weight 88.4 kg

Rated values
Phases 3 Ph
Nominal frequency [Hz] 60 Hz
Control Not controllable

Classification
IP protection rating IP65
Certifications CE, UL
Efficiency rating (ErP) E15

Dimensions
Width 1380 mm
Height 1380 mm
Total depth 652 mm
Diameter 1270 mm

Rated values 60 Hz
Elektrische Nennleistung 1.536 kW
Nominal voltage star connection 400 V
Voltage tolerance -10 - 10 %
Nominal current star connection 3,3 A
Speed 790 U/min
Power factor 0.74
Ambient temperature -40 - 40 °C
Sound power level Lw 90 dB
Sound pressure level Lp 54 dB

Volumetric flow rate 60 Hz
Characteristic curve – 0 Pa 43200 m³/h
Characteristic curve – 10 Pa 41700 m³/h
Characteristic curve – 20 Pa 39800 m³/h
Characteristic curve – 30 Pa 37800 m³/h
Characteristic curve – 40 Pa 35700 m³/h
Characteristic curve – 50 Pa 33600 m³/h
Characteristic curve – 60 Pa 31400 m³/h
Characteristic curve – 70 Pa 29100 m³/h
Characteristic curve – 80 Pa 26800 m³/h
Characteristic curve – 90 Pa 24300 m³/h
Characteristic curve – 100 Pa 21400 m³/h

Spec. power 60 Hz
Characteristic curve – 0 Pa 39 W/(1000m³/h)
Characteristic curve – 10 Pa 41 W/(1000m³/h)
Characteristic curve – 20 Pa 43 W/(1000m³/h)
Characteristic curve – 30 Pa 45 W/(1000m³/h)
Characteristic curve – 40 Pa 47 W/(1000m³/h)
Characteristic curve – 50 Pa 49 W/(1000m³/h)
Characteristic curve – 60 Pa 51 W/(1000m³/h)
Characteristic curve – 70 Pa 54 W/(1000m³/h)
Characteristic curve – 80 Pa 58 W/(1000m³/h)
Characteristic curve – 90 Pa 62 W/(1000m³/h)
Characteristic curve – 100 Pa 69 W/(1000m³/h)
Technical datasheet

Illustrations may show accessories that are not included in the scope of delivery.
Due to constant further development of our products, illustrations and technical data may deviate slightly. Errors and omissions excepted.