Fan BD-Blue 130C ON/OFF mot 400-3-50 3.3A 48400m³/h T

SKU
60-25-4605
Sales unit 1 pc
Availability Available for order

Basic data
Montiert Mounted
Thermal protection contact No
Type Installation at a wall
Weight 88.4 kg

Rated values
Phases 3 Ph
Nominal frequency [Hz] 50 Hz
Control Not controllable

Classification
IP protection rating IP65
Certifications CE, UL
Efficiency rating (ErP) E15

Dimensions
Width 1380 mm
Height 1380 mm
Total depth 1060 mm
Diameter 1270 mm
Other dimension 1600 mm

Rated values 50 Hz
Elektrische Nennleistung 1.48 kW
Nominal voltage star connection 400 V
Voltage tolerance -10 - 10 %
Nominal current star connection 3,3 A
Speed 680 U/min
Power factor 0.71
Ambient temperature -40 - 40 °C
Sound power level Lw 86 dB
Sound pressure level Lp 62 dB

Volumetric flow rate 50 Hz
Characteristic curve – 0 Pa 48400 m³/h
Characteristic curve – 10 Pa 46400 m³/h
Characteristic curve – 20 Pa 43600 m³/h
Characteristic curve – 30 Pa 40700 m³/h
Characteristic curve – 40 Pa 38000 m³/h
Characteristic curve – 50 Pa 35300 m³/h
Characteristic curve – 60 Pa 32300 m³/h
Characteristic curve – 70 Pa 28800 m³/h
Characteristic curve – 80 Pa 24400 m³/h

Spec. power 50 Hz
Characteristic curve – 0 Pa 30 W/(1000m³/h)
Characteristic curve – 10 Pa 32 W/(1000m³/h)
Characteristic curve – 20 Pa 34 W/(1000m³/h)
Characteristic curve – 30 Pa 37 W/(1000m³/h)
Characteristic curve – 40 Pa 40 W/(1000m³/h)
Characteristic curve – 50 Pa 43 W/(1000m³/h)
Characteristic curve – 60 Pa 47 W/(1000m³/h)
Characteristic curve – 70 Pa 51 W/(1000m³/h)
Characteristic curve – 80 Pa 59 W/(1000m³/h)
Technical datasheet

Illustrations may show accessories that are not included in the scope of delivery.
Due to constant further development of our products, illustrations and technical data may deviate slightly. Errors and omissions excepted.